Description
Downloads
Accessories supplied with the unit
Test probe with protective cap, crocodile clip, spiral measuring cable, PE measuring adapter incl. fixed adapter for socket type 12, lap belt, 4 batteries type AA (LR6), test certificate, operating and calibration instructions
Detailed description
- If an external voltage is present, the effective value is measured and displayed
- Measurement according to EN61557-4: Measuring current >200mA with automatic polarity reversal, open circuit voltage 4V to 6V (0.2-2Ω)
- Measuring range 0.00Ω to 20.0Ω
- Measuring accuracy ±0.07Ω from 0.00Ω to 0.50Ω; ±10% ±0.02Ω from 0.50Ω to 2.00Ω
- Function for automatic zero adjustment of the measuring leads and other measuring accessories (max. 4Ω)
- LC display with red and blue backlighting:
- Resistance < 1Ω is signaled with a loud signal tone (can be switched off)
- Acoustic and visual warning when an external voltage is present, display of the effective value
- Integrated cable reel with fused measuring cable (30m x 1mm2, 4mm safety laboratory plug)
- Test lead resistance compensated at the factory
- AUX socket for connecting other measuring accessories instead of the integrated reel or for using the reel with other measuring devices
- Cable reel cover can be easily removed to replace the test lead
- Hands and shoulders remain free thanks to lap belt
- Standard 4mm connection sockets
- Powered by 4 AA batteries for up to 10,000 measurements
– red: “Bad” (resistance >1Ω)
– Blue: “Good” (resistance <1Ω)
Physically
– by Standard Electrical safety in accordance with EN/IEC 61010-1:2008: protective insulation, 600V CAT III / 300V CAT IV (pollution degree 1 and 2) or 300V CAT III / 300V CAT IV (pollution degree 3)
– Dimensions | Ø: 170mm
– Weight 2,1 kg